XT30 SMOKE STOPPER BY BENGINEERING LABS - MODERN LED XT30 SMOKE STOPPER BY BENGINEERING LABS - MODERN LED Catalyst Machineworks Quickly know whether your quad has a short, and protect it from certain peril. By plugging this in between your battery and your quad, you can limit the current getting to your quad. If the LED is on, there is no short. If the LED is faded, blinking, or off, then there is a short and you should check your quad. This is a great tool, but we recommend you pair it with the use of a multimeter to check for shorts to be sure you are not going to toast your precious goods! Smoke Stopper uses a Resettable fuse (PPTC). Connectors are high quality Amass XT30's.    Specs XT30 1-5s capable (24v Max) 1.1A Hold Current, 2.2A Trip Current 0.5S Trip time Usage Plug the Solid State Smoke Inhibitor between the battery and the device. Green led on, OK. Green led dim or blinking, Fuse tripped. Green led off, Shorted. To reset the Solid State Smoke Inhibitor, unplug for 10 seconds. Note: Solid State Smoke Inhibitor/ Lightbulbs / Fuses / Circuit breakers are not 100% foolproof way of keeping the magic smoke in. It’s always best to use in conjunction with a multimeter.

XT30 SMOKE STOPPER BY BENGINEERING LABS - MODERN LED

Code: CM00816

Quickly know whether your quad has a short, and protect it from certain peril. By plugging this in between your battery and your quad, you can limit the current getting to your quad. If the LED is on, there is no short. If the LED is faded, blinking, or off, then there is a short and you should check your quad. This is a great tool, but we recommend you pair it with the use of a multimeter to check for shorts to be sure you are not going to toast your precious goods!

Smoke Stopper uses a Resettable fuse (PPTC). Connectors are high quality Amass XT30's.

 

 Specs

  • XT30
  • 1-5s capable (24v Max)
  • 1.1A Hold Current, 2.2A Trip Current
  • 0.5S Trip time

Usage

Plug the Solid State Smoke Inhibitor between the battery and the device.

  • Green led on, OK.
  • Green led dim or blinking, Fuse tripped.
  • Green led off, Shorted.

To reset the Solid State Smoke Inhibitor, unplug for 10 seconds.

Note: Solid State Smoke Inhibitor/ Lightbulbs / Fuses / Circuit breakers are not 100% foolproof way of keeping the magic smoke in. It’s always best to use in conjunction with a multimeter.

Quickly know whether your quad has a short, and protect it from certain peril. By plugging this in between your battery and your quad, you can limit the current getting to your quad. If the LED is on, there is no short. If the LED is faded, blinking, or off, then there is a short and you should check your quad. This is a great tool, but we recommend you pair it with the use of a multimeter to check for shorts to be sure you are not going to toast your precious goods!

Smoke Stopper uses a Resettable fuse (PPTC). Connectors are high quality Amass XT30's.

 

 Specs

  • XT30
  • 1-5s capable (24v Max)
  • 1.1A Hold Current, 2.2A Trip Current
  • 0.5S Trip time

Usage

Plug the Solid State Smoke Inhibitor between the battery and the device.

  • Green led on, OK.
  • Green led dim or blinking, Fuse tripped.
  • Green led off, Shorted.

To reset the Solid State Smoke Inhibitor, unplug for 10 seconds.

Note: Solid State Smoke Inhibitor/ Lightbulbs / Fuses / Circuit breakers are not 100% foolproof way of keeping the magic smoke in. It’s always best to use in conjunction with a multimeter.